Files
whipper-gui/morituri/program/arc.py
Samantha Baldwin d1ed80d62a argparse & logging (#92)
* introduce logcommand.Lager, Whipper(); use argparse for whipper image commands, stub logging

* update Lager docstring to mention config.Config()

* make incorrect subcommand and --version work on toplevel command

* migrate accurip show, expand Lager, do not attempt to return from Lager.__init__.

* migrate offset find, add Lager.error

* correct offset find drive symlink handling

* migrate drive

* change Lager.__init__(prog) to arg from kwarg

* but actually

* remove Whipper.usage

* add and use Lager.device_option() context manager

* help I married an axe murderer

* use unified options namespace for entire command tree

* migrate whipper cd without comprehensive config loading

* switch to logging module

- use logging instead of flog for non-extern modules
- use WHIPPER_DEBUG and WHIPPER_LOGFILE env variables

* convert self.log calls to logger.debug

* convert self.error calls to logger.error

* remove log.Loggable, use logger not logging

* Logging conversion continues

- Convert log.* calls to logger.*
- Remove morituri.common.log imports

* remove morituri.common.log from tests

* remove extern/flog, bare minimum Debug conversion

* update README for logging changes

* update soxi to use logging

* refactor Lager for more declarative subcommands

* Refactor Lager.device_option:

- inline into __init__
- throw IOError instead of Exception for missing drives
- remove CommandError checking in rip/main

* rename rip to whipper in rip.main

* convert rip.debug commands

* Rename logcommand.Lager to command.BaseCommand

- remove command.CommandError occurrences
- remove python-command external module

* remove submodules from README, update rclog formatter

* update minor ambiguity in readme for command invocation

* update version number to match setup.py

* remove gitmodules

* update version number in tests as well (boo)

* convert logger.error to logger.critical

* Change morituri.rip to morituri.command

- mv common.command to command.basecommand
- move TEMPLATES used only by rip.cd out of rip.common
- update entry point for command to command.main

* update basecommand documentation

* go pyflaking: import fixing

* replace self.stdout with sys.stdout

* remove BaseCommand.config, alphabetise imports

* convert self.stdXXX leftovers

* convert last getRootCommand to config.Config

* convert last getExceptionMessage's to str

* change musicbrainz useragent to whipper
2016-12-20 23:11:30 +01:00

53 lines
1.2 KiB
Python

from os.path import exists
from subprocess import Popen, PIPE
import logging
logger = logging.getLogger(__name__)
ARB = 'accuraterip-checksum'
FLAC = 'flac'
def accuraterip_checksum(f, track, tracks, wave=False, v2=False):
v = '--accuraterip-v1'
if v2:
v = '--accuraterip-v2'
track, tracks = str(track), str(tracks)
if not wave:
flac = Popen([FLAC, '-cds', f], stdout=PIPE)
arc = Popen([ARB, v, '/dev/stdin', track, tracks],
stdin=flac.stdout, stdout=PIPE, stderr=PIPE)
else:
arc = Popen([ARB, v, f, track, tracks],
stdout=PIPE, stderr=PIPE)
if not wave:
flac.stdout.close()
out, err = arc.communicate()
if not wave:
flac.wait()
flac_rc = flac.returncode
arc_rc = arc.returncode
if not wave and flac_rc != 0:
logger.warning('ARC calculation failed: flac return code is non zero')
return None
if arc_rc != 0:
logger.warning('ARC calculation failed: arc return code is non zero')
return None
out = out.strip()
try:
outh = int('0x%s' % out, base=16)
except ValueError:
logger.warning('ARC output is not usable')
return None
return outh